
TeSys D contactor - 4P(4 NO) - AC-1 - <= 440 V 80 A - 240 V AC 50/60 Hz coil
Show more characteristics >-
Characteristics
Main range TeSysproduct name TeSys Dproduct or component type Contactordevice short name LC1Dcontactor application Resistive loadutilisation category AC-1poles description 4Ppower pole contact composition 4 NO[Ue] rated operational voltage <= 300 V DC for power circuit<= 690 V AC 25...400 Hz for power circuit[Ie] rated operational current 80 A (<= 60 °C) at <= 440 V AC AC-1 for power circuitcontrol circuit type AC 50/60 Hz[Uc] control circuit voltage 240 V AC 50/60 Hzauxiliary contact composition 1 NO + 1 NC[Uimp] rated impulse withstand voltage Conforming to IEC 60947overvoltage category III[Ith] conventional free air thermal current 80 A at <= 60 °C for power circuit10 A at <= 60 °C for signalling circuitIrms rated making capacity 1000 A at 440 V for power circuit conforming to IEC 60947140 A AC for signalling circuit conforming to IEC 60947-5-1250 A DC for signalling circuit conforming to IEC 60947-5-1rated breaking capacity 1000 A at 440 V for power circuit conforming to IEC 60947[Icw] rated short-time withstand current 100 A 1 s signalling circuit120 A 500 ms signalling circuit140 A 100 ms signalling circuit520 A <= 40 °C 10 s power circuit900 A <= 40 °C 1 s power circuit110 A <= 40 °C 10 min power circuit260 A <= 40 °C 1 min power circuitassociated fuse rating 125 A gG at <= 690 V coordination type 1 for power circuit125 A gG at <= 690 V coordination type 2 for power circuit10 A gG for signalling circuit conforming to IEC 60947-5-1average impedance 1.6 mOhm at 50 Hz - Ith 80 A for power circuit[Ui] rated insulation voltage 600 V for power circuit certifications CSA600 V for power circuit certifications UL690 V for power circuit conforming to IEC 60947-4-1690 V for signalling circuit conforming to IEC 60947-1600 V for signalling circuit certifications CSA600 V for signalling circuit certifications ULelectrical durability 1.4 Mcycles 80 A AC-1 at Ue <= 440 Vpower dissipation per pole 10.2 W AC-1safety cover Withmounting support PlateRailstandards CSA C22.2 No 14EN 60947-4-1EN 60947-5-1IEC 60947-4-1IEC 60947-5-1UL 508product certifications GLLROS (Lloyds register of shipping)DNVBVULGOSTRINACSACCCconnections - terminals Control circuit : spring terminals 1 cable(s) 2.5 mm² - cable stiffness: flexible - without cable endControl circuit : spring terminals 2 cable(s) 2.5 mm² - cable stiffness: flexible - without cable endPower circuit : spring clamp terminal 1 cable(s) 1...35 mm² - cable stiffness: flexible - with cable endPower circuit : spring clamp terminal 1 cable(s) 1...35 mm² - cable stiffness: solid - without cable endPower circuit : spring clamp terminal 2 cable(s) 1...25 mm² - cable stiffness: solid - without cable endPower circuit : spring clamp terminal 1 cable(s) 1...35 mm² - cable stiffness: flexible - without cable endPower circuit : spring clamp terminal 2 cable(s) 1...25 mm² - cable stiffness: flexible - without cable endPower circuit : spring clamp terminal 2 cable(s) 1...25 mm² - cable stiffness: flexible - with cable endtightening torque Power circuit : 8 N.m - on screw clamp terminals - cable 25...35 mm² hexagonal 4 mmPower circuit : 5 N.m - on screw clamp terminals - cable 2.5...25 mm² hexagonal 4 mmoperating time 12...26 ms closing4...19 ms openingsafety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1mechanical durability 6 Mcyclesoperating rate 3600 cyc/h at <= 60 °CComplementary coil technology Without built-in suppressor modulecontrol circuit voltage limits 0.3...0.6 Uc drop-out at 60 °C, AC 50/60 Hz0.8...1.1 Uc operational at 60 °C, AC 50 Hz0.85...1.1 Uc operational at 60 °C, AC 60 Hzinrush power in VA 140 VA at 20 °C (cos ϕ 0.75) 60 Hz160 VA at 20 °C (cos ϕ 0.75) 50 Hzhold-in power consumption in VA 13 VA at 20 °C (cos ϕ 0.3) 60 Hz15 VA at 20 °C (cos ϕ 0.3) 50 Hzheat dissipation 4...5 W at 50/60 Hzauxiliary contacts type Type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1Type mirror contact (1 NC) conforming to IEC 60947-4-1signalling circuit frequency 25...400 Hzminimum switching current 5 mA for signalling circuitminimum switching voltage 17 V for signalling circuitnon-overlap time 1.5 ms on de-energisation (between NC and NO contact)1.5 ms on energisation (between NC and NO contact)insulation resistance > 10 MOhm for signalling circuitEnvironment IP degree of protection IP20 front face conforming to IEC 60529protective treatment TH conforming to IEC 60068-2-30pollution degree 3ambient air temperature for operation -5...60 °Cambient air temperature for storage -60...80 °Cpermissible ambient air temperature around the device -40...70 °C at Ucoperating altitude 3000 m without derating in temperaturefire resistance 850 °C conforming to IEC 60695-2-1flame retardance V1 conforming to UL 94mechanical robustness Vibrations contactor open 2 Gn, 5...300 HzVibrations contactor closed 4 Gn, 5...300 HzShocks contactor open 10 Gn for 11 msShocks contactor closed 15 Gn for 11 msheight 122 mmwidth 70 mmdepth 120 mmproduct weight 1.15 kgOffer Sustainability Sustainable offer status Green Premium productRoHS (date code: YYWW) REACh Product environmental profile Product end of life instructions Need no specific recycling operationsContractual warranty Warranty period 18 months -
Documents and Downloads
Language- English
CADSizeAdd to My Documents4P EVERLINK CONT 60A AC1 (Version 1.0)CertificateSizeAdd to My DocumentsCCC Cert TeSys D - LC.D40A-80A_LC.DT60A-80A, France (Version 1.0)Instruction sheetSizeAdd to My DocumentsLC1DT..A, LC1DT..A3 Everlink 4-pole contactors 60 to 80 A AC-1 - Instruction sheet (Version 07)Date 23/05/18Size 2.8 MBProduct Environmental ProfileSizeAdd to My Documents -
Technical FAQs
No results foundUnfortunately, related FAQs are unavailable due to temporary technical issues. Please try again later.